Funiculus connector 1/2″ superflexus, DIN 7/16 masculus ad DIN 7/16 masculum angulus rectus


  • Locus Originis:Shanghai, Sina (Continens)
  • Nomen Marcae:Telsto
  • Numerus Modeli:Funiculus connector 1/2s masculus DIN rectus ad angulum rectum
  • Applicatio:Coniunctio funium
  • Inauguratio:Nickel/aurum
  • Materia:Cuprum
  • Insulator:Teflon/Materia plastica
  • Impedentia:50 ohmia
  • Durabilitas:Quingenti cycli
  • Ambitus temperaturae:-65°C~+165°C
  • Typus:Coniunctio funium
  • Descriptio

    Specificationes

    Auxilium Producti

    Nomen typi Funiculus connector 1/2"s masculus DIN rectus ad angulum rectum
    Impedentia 50Ω
    Vibratio 100m/S² (10~500Hz)
    Frequentiae Ambitus DC-6GHz
    Amissio Insertionis ≤ 0.15dB/6GHz
    Tensioni Resistenti 4000V rms ad planitiem maris
    Tensio Operativa 2700Vr.ms ad planitiem maris
    Potentia media 3Kw maximus
    Resistentia Insulationis ≥ 10000 MΩ
    Vis retentionis conductoris centralis ≥ 6N
    Durabilitas ≥ 500 (cycli)
    Resistentia contactus Contactus Centralis ≤ 0.4mΩ
    Contactus externus ≤ 1.5mΩ
    Ratio Undae Stabilis Tensionis Recta ≤ 1.20/6GHz
    Angulus rectus ≤ 1.35/6GHz

    1. Coniunctor coaxialis RF

    1.1 Materiae et Involucrum Coniunctorum
    Conductor internus Aes, argento obductum, crassitudine inaurationis ≥0.003mm
    Conductor externus Aes, mixtura ternaria obductum, crassitudine inaurationis ≥ 0.002 mm
    Fibula: Aeris Insulatio
    dielectricum PTFE
    1.2 Proprietates Electricae et Mechanicae
    Impedantiam proprietatum: 50Ω
    Frequentiae amplitudo DC-3GHz
    SWR ≤1.15 (DC-3GHz)
    Robur dielectricum ≥2500V
    Resistentia contactus conductor internus ≤1.0mΩ, conductor externus ≤0.4mΩ
    Resistentia insulatoris ≥5000MΩ (500V DC)
    SWR ≤1.15 (DC-3GHz)
    PIM(IM3) ≤-155dBc@2x43dBm
    Firmitas connectoris ≥500 cycli

    2. Funis coaxialis RF: Funis RF Superflexibilis 1/2"

    2.1 Materiae
    Conductor internus filum aluminii cupro obductum (φ3.60mm)
    Dielectricum insulationis spuma polyethylena (φ8.90mm)
    Conductor externus Tubus aeneus corrugatus (φ12.20mm)
    Tunica funis PE (φ13.60mm)
    2.2 Proprietas
    Impedantiam characteristicam 50Ω
    Condensator ordinarius 80pF/m
    Frequentia transmissionis 83%
    Radius flexionis singularis minimus 50mm
    Robur tensile 700N
    Resistentia insulationis ≥5000MΩ
    Attenuatio munitionis ≥120dB
    SWR ≤1.15 (0.01-3GHz)

    3. Funis saltatorius

    3.1 Magnitudo Partis Funis
    Longitudo totalis coniunctionum funium 1000mm±10, 2000mm±20, 3000mm±25, 5000mm±40
    3.2 Proprietas electrica
    Frequentiae Fascia 800-2700MHz
    Impedentia Characteres 50Ω±2
    Tensio Operativa 1500V
    SWR ≤1.11 (0.8-2.2GHz), ≤1.18 (2.2-2.7GHz)
    Tensio insulationis ≥2500V
    Resistentia insulationis ≥5000MΩ (500V DC)
    PIM(IM3) ≤-155dBc @ 2x20W
    3.3 Proprietas ambitus
    Impermeabilis IP68
    Ambitus temperaturae operationis -40℃ ad +85℃
    Ambitus temperaturae repositionis -70℃ ad +85℃

    3.4 Iactura Insertionis:

    Frequentia 1m 2m 3m 5m
    890-960MHz ≤0.15dB ≤0.26dB ≤0.36dB ≤0.54dB
    1710-1880MHz ≤0.20dB ≤0.36dB ≤0.52dB ≤0.80dB
    1920-2200MHz ≤0.26dB ≤0.42dB ≤0.58dB ≤0.92dB
    2500-2690MHz ≤0.30dB ≤0.50dB ≤0.70dB ≤1.02dB
    5800-5900MHz ≤0.32dB ≤0.64dB ≤0.96dB ≤1.6dB

    Referentia Sarcinae

    Funes saltatorii
    Sarcina funis saltatorii

  • Praecedens:
  • Deinde:

  • Instructiones institutionis funis superflexibilis N vel 7 / 16 vel 4310 1 / 2″

    Structura connectoris: (Fig. 1)
    A. nux anterior
    B. nux posterior
    C. obturaculum

    Instructiones Installationis001

    Dimensiones nudationis in diagramma (Fig. 2) monstrantur; dum nudatur, attendendum est:
    1. Superficies extrema conductoris interni limatura esse debet.
    2. Impuritates, ut squamam cupri et lapam, ex superficie extrema funis remove.

    Instructiones Installationis002

    Partis obturantis componenda: Partem obturantem secundum conductorem externum funis, ut in diagramma (Fig. 3) monstratur, cochleis adfige.

    Instructiones Installationis003

    Nucem posteriorem componendo (Fig. 3).

    Instructiones Installationis004

    Nucem anteriorem et posteriorem constringendo, ut in diagramma demonstratur (Fig. (5)), coniunge.
    1. Antequam cochleas, stratum pinguedinis lubricantis anulo torico perunge.
    2. Nucem posteriorem et funem immobiles tene, corpus testae principalis corpori testae posteriori adstringe. Corpus testae principalis corporis testae posterioris clave simiae adstringe. Assemblatio perfecta est.

    Instructiones Installationis005

    Nuntium tuum hic scribe et nobis mitte.